About this product
- The inverted format is a stable, ergonomic platform for cell cultures, multi-well plates, and larger specimen containers.
- Five plan-achromatic objective lenses and two sets of eyepieces provide nine unique magnifications ranging from 40X to 1500X
- The infinity-corrected optical system eliminates certain optical errors when using filters and other in-line components, ensuring highly-precise images.
- Specialized 10X, 20X, and 40X objective lenses are included for phase-contrast applications, further improved by the fully-customizable Koehler illumination system.
- Includes a 18MP USB 3.0 camera and specialized microscopy software for PC, Mac, and Linux
The IN480T provides high-resolution optics and a versatile illumination system in a stable, ergonomic design for observing cell cultures and other biological and chemical specimens. The inverted form accommodates larger specimen containers, with multiple specimen templates and mechanical stage controls to improve workflow. High-resolution optics and phase-contrast capability maximize contrast and clarity to ensure high quality images.
The viewing head has a 45° incline and Siedentopf interpupillary adjustment for flexibility and comfort. The trinocular format provides a dedicated photo-port for mounting a microscopy camera for capturing photos or videos.
The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly-precise images. Five brightfield objective lenses and two sets of eyepieces provide a wide magnification range from 40X to 1500X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.
The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. The ability to center the lamp and condenser, along with the field and aperture diaphragms, allow for highly-efficient, optimized illumination for maximum resolution. Along with height adjustment, the condenser can be swung out of the light path. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting which can be used with colored filters for band-isolation or color-correction.
The 18MP USB 3.0 digital camera captures still images and video, and allows you to view a live stream on your PC. With software available for Windows, Mac, and Linux, it's a multi-platform imaging solution. The included Windows software offers image-development and measurement tools, as well as advanced compositing features such as image-stitching and extended-depth-of-focus. Independent preview and capture resolutions allow you to view high-speed video while capturing high-definition images. For Mac and Linux, there is a lite version with limited processing features.
This microscope operates on 90-240V wide-band voltage for use in multiple international regions.
Specifications
Optical System |
Infinity-corrected |
|
Head |
Trinocular, 45° incline |
|
Interpupillary Adjustment |
Siedentopf compensation-free gemel, 50mm-76mm |
|
Ocular Diameter |
30mm |
|
Eyepieces |
10X FN22mm plan wide-field, 25X wide-field |
|
Photo-port |
CX-type height-adjustable, 23mm tube |
|
Objective Turret |
quintuple |
|
Focusing System |
Focus Adjustment |
Coaxial Coarse/Fine, adjustable tension |
Fine Division |
0.002mm |
Coarse Stroke |
38mm |
Fine Stroke |
0.2mm |
|
|
Stage |
fixed-height, mechanical X-Y translation |
|
Stage Dimensions |
160mm x 250mm stage extension: 70mm x 180mm |
|
Stage X-Y Travel Range |
120mm x 80mm |
|
Specimen Holders |
Terasaki plate, Petri dish |
|
Transmitted Illumination |
6V 30W halogen variable intensity centerable lamp |
|
Condenser |
NA 0.3, centerable |
|
Condenser Working Distance |
72mm maximum |
|
Phase Contrast Annuli |
4X/10X and 20X/40X |
|
Power |
90-240VAC 50/60Hz wide-band |
|
Objective Lenses
Magnification |
Corrections |
NA |
Working Distance |
Cover-glass Thickness |
4X |
plan achromatic |
0.13 |
10.4mm |
1.5mm |
10X |
plan achromatic |
0.25 |
7.30mm |
1.5mm |
20X |
plan achromatic |
0.40 |
6.79mm |
1.5mm |
40X |
plan achromatic |
0.60 |
3.08mm |
1.5mm |
60X |
plan achromatic |
0.70 |
1.71mm |
1.5mm |
10X |
phase-ring |
0.25 |
7.30mm |
1.5mm |
20X |
phase-ring |
0.40 |
6.80mm |
1.5mm |
40X |
phase-ring |
0.60 |
3.08mm |
1.5mm |
Magnification Chart
Eyepiece |
Objective |
4X |
10X |
20X |
40X |
60X |
10X |
40X |
100X |
200X |
400X |
600X |
25X |
100X |
250X |
500X |
1000X |
1500X |
Camera Specifications
Sensor Type |
CMOS |
|
Sensor Optical Format |
1/2.3" |
|
Active Pixels |
18M (4912 x 3684) |
|
Pixel Size |
1.25µm x 1.25µm |
|
Active Sensor Area |
6.14mm x 4.61mm |
|
Shutter |
electronic rolling shutter |
|
Sensitivity |
0.62V/Lux-sec |
|
Spectral Response |
380-650nm with IR-cut filter |
|
Capture Resolution and Framerate |
5.6fps @ 4912x3684 18.1fps @ 2456x1842 32.2fps @ 1228x922 |
|
Connectivity |
USB 3.0 |
|
|
Lens-mount |
C-mount |
|
Compensating Lens |
0.5X |
|
Power |
5VDC over USB |
|
Software
OS Requirements |
Windows (32/64 bit) XP/Vista/7/8/10, Mac OS 10.8+, Linux kernel 3.13+ |
Hardware Requirements |
Intel Core2 2.8GHz or comparable processor, 4GB RAM |
Features |
Windows Version |
Live video preview |
Captures still images and video |
Time-lapse capture |
Exposure and white-balance controls |
Dark-field correction |
Digital binning |
Image processing |
Measurement tools, including lines, arcs, polygons |
Segmentation and counting tools |
Image-stitching, extended depth-of-field, HDR |
Fluorescence color-mapping |
Mac/Linux Versions |
Live video preview |
Captures still images and video |
Exposure control |
Color adjustment |
Measurement tools, including lines, arcs, polygons |
|
Contents:
One microscope
One photo port
One mechanical stage attachment
One condenser
Five brightfield objective lenses
Three phase-contrast objective lenses
One pair of 10X eyepieces
One pair of 25X eyepieces
One glass stage insert
One metal stage insert
Three specimen holders
One phase-contrast annulus board
One centering telescope
Two bulbs
One power cable
One dust cover
One USB camera
One C-mount reduction lens
Two sizing adapters for reduction lens